๐Ÿ’พ Data Updated: 2025 HTS Revision 30 โ€ข Last updated: November 24, 2025

4411.13.20.00 - Laminated boards bonded in whole or in part, or impregnated, with synthetic resins

Details

FieldValue
Unit of Quantitykg, m3
General Rate of Duty1.9ยข/kg + 1.5%
Special Rate of DutyFree (A,AU,BH,CL,CO,D,E,IL,JO,KR,MA,OM,P,PA,PE,S,SG)
A ๐Ÿ‡ฆ๐Ÿ‡ซ ๐Ÿ‡ฆ๐Ÿ‡ฑ ๐Ÿ‡ฉ๐Ÿ‡ฟ ๐Ÿ‡ฆ๐Ÿ‡ด ๐Ÿ‡ฆ๐Ÿ‡ฎ ๐Ÿ‡ฆ๐Ÿ‡ท ๐Ÿ‡ฆ๐Ÿ‡ฒ ๐Ÿ‡ฆ๐Ÿ‡ฟ ๐Ÿ‡ง๐Ÿ‡ฟ ๐Ÿ‡ง๐Ÿ‡ฏ ๐Ÿ‡ง๐Ÿ‡น ๐Ÿ‡ง๐Ÿ‡ด ๐Ÿ‡ง๐Ÿ‡ฆ ๐Ÿ‡ง๐Ÿ‡ผ ๐Ÿ‡ง๐Ÿ‡ท ๐Ÿ‡ฎ๐Ÿ‡ด ๐Ÿ‡ป๐Ÿ‡ฌ ๐Ÿ‡ง๐Ÿ‡ซ ๐Ÿ‡ง๐Ÿ‡ฎ ๐Ÿ‡จ๐Ÿ‡ป ๐Ÿ‡ฐ๐Ÿ‡ญ ๐Ÿ‡จ๐Ÿ‡ฒ ๐Ÿ‡จ๐Ÿ‡ซ ๐Ÿ‡น๐Ÿ‡ฉ ๐Ÿ‡จ๐Ÿ‡ฝ ๐Ÿ‡จ๐Ÿ‡จ ๐Ÿ‡ฐ๐Ÿ‡ฒ ๐Ÿ‡จ๐Ÿ‡ฐ ๐Ÿ‡จ๐Ÿ‡ฎ ๐Ÿ‡จ๐Ÿ‡ฉ ๐Ÿ‡ฉ๐Ÿ‡ฏ ๐Ÿ‡ฉ๐Ÿ‡ฒ ๐Ÿ‡ช๐Ÿ‡จ ๐Ÿ‡ช๐Ÿ‡ฌ ๐Ÿ‡ช๐Ÿ‡ท ๐Ÿ‡ธ๐Ÿ‡ฟ ๐Ÿ‡ช๐Ÿ‡น ๐Ÿ‡ซ๐Ÿ‡ฐ ๐Ÿ‡ซ๐Ÿ‡ฏ ๐Ÿ‡ฌ๐Ÿ‡ฆ ๐Ÿ‡ฌ๐Ÿ‡ฒ ๐Ÿ‡ต๐Ÿ‡ธ ๐Ÿ‡ฌ๐Ÿ‡ช ๐Ÿ‡ฌ๐Ÿ‡ญ ๐Ÿ‡ฌ๐Ÿ‡ฉ ๐Ÿ‡ฌ๐Ÿ‡ณ ๐Ÿ‡ฌ๐Ÿ‡ผ ๐Ÿ‡ฌ๐Ÿ‡พ ๐Ÿ‡ญ๐Ÿ‡น ๐Ÿ‡ญ๐Ÿ‡ฒ ๐Ÿ‡ฎ๐Ÿ‡ฉ ๐Ÿ‡ฎ๐Ÿ‡ถ ๐Ÿ‡ฏ๐Ÿ‡ฒ ๐Ÿ‡ฏ๐Ÿ‡ด ๐Ÿ‡ฐ๐Ÿ‡ฟ ๐Ÿ‡ฐ๐Ÿ‡ช ๐Ÿ‡ฐ๐Ÿ‡ฎ KO ๐Ÿ‡ฐ๐Ÿ‡ฌ ๐Ÿ‡ฑ๐Ÿ‡ง ๐Ÿ‡ฑ๐Ÿ‡ธ ๐Ÿ‡ฑ๐Ÿ‡ท ๐Ÿ‡ฒ๐Ÿ‡ฌ ๐Ÿ‡ฒ๐Ÿ‡ผ ๐Ÿ‡ฒ๐Ÿ‡ป ๐Ÿ‡ฒ๐Ÿ‡ฑ ๐Ÿ‡ฒ๐Ÿ‡ท ๐Ÿ‡ฒ๐Ÿ‡บ ๐Ÿ‡ฒ๐Ÿ‡ฉ ๐Ÿ‡ฒ๐Ÿ‡ณ ๐Ÿ‡ฒ๐Ÿ‡ช ๐Ÿ‡ฒ๐Ÿ‡ธ ๐Ÿ‡ฒ๐Ÿ‡ฟ ๐Ÿ‡ฒ๐Ÿ‡ฒ ๐Ÿ‡ณ๐Ÿ‡ฆ ๐Ÿ‡ณ๐Ÿ‡ต ๐Ÿ‡ณ๐Ÿ‡ช ๐Ÿ‡ณ๐Ÿ‡ฌ ๐Ÿ‡ณ๐Ÿ‡บ ๐Ÿ‡ณ๐Ÿ‡ซ ๐Ÿ‡ฒ๐Ÿ‡ฐ ๐Ÿ‡ต๐Ÿ‡ฐ ๐Ÿ‡ต๐Ÿ‡ฌ ๐Ÿ‡ต๐Ÿ‡พ ๐Ÿ‡ต๐Ÿ‡ญ ๐Ÿ‡ต๐Ÿ‡ณ ๐Ÿ‡จ๐Ÿ‡ฌ ๐Ÿ‡ท๐Ÿ‡ผ ๐Ÿ‡ธ๐Ÿ‡ญ ๐Ÿ‡ฑ๐Ÿ‡จ ๐Ÿ‡ป๐Ÿ‡จ ๐Ÿ‡ผ๐Ÿ‡ธ ๐Ÿ‡ธ๐Ÿ‡ณ ๐Ÿ‡ท๐Ÿ‡ธ ๐Ÿ‡ธ๐Ÿ‡ฑ ๐Ÿ‡ธ๐Ÿ‡ง ๐Ÿ‡ธ๐Ÿ‡ด ๐Ÿ‡ฟ๐Ÿ‡ฆ ๐Ÿ‡ธ๐Ÿ‡ธ ๐Ÿ‡ฑ๐Ÿ‡ฐ ๐Ÿ‡ธ๐Ÿ‡ท ๐Ÿ‡ธ๐Ÿ‡น ๐Ÿ‡น๐Ÿ‡ฟ ๐Ÿ‡น๐Ÿ‡ญ ๐Ÿ‡น๐Ÿ‡ฑ ๐Ÿ‡น๐Ÿ‡ฌ ๐Ÿ‡น๐Ÿ‡ฐ ๐Ÿ‡น๐Ÿ‡ด ๐Ÿ‡น๐Ÿ‡ณ ๐Ÿ‡น๐Ÿ‡ป ๐Ÿ‡บ๐Ÿ‡ฌ ๐Ÿ‡บ๐Ÿ‡ฆ ๐Ÿ‡บ๐Ÿ‡ฟ ๐Ÿ‡ป๐Ÿ‡บ ๐Ÿ‡ผ๐Ÿ‡ซ ๐Ÿ‡ต๐Ÿ‡ธ ๐Ÿ‡ช๐Ÿ‡ญ ๐Ÿ‡พ๐Ÿ‡ช ๐Ÿ‡ฟ๐Ÿ‡ฒ ๐Ÿ‡ฟ๐Ÿ‡ผ
AU ๐Ÿ‡ฆ๐Ÿ‡บ
BH ๐Ÿ‡ง๐Ÿ‡ญ
CL ๐Ÿ‡จ๐Ÿ‡ฑ
CO ๐Ÿ‡จ๐Ÿ‡ด
D ๐Ÿ‡ฆ๐Ÿ‡ด ๐Ÿ‡ง๐Ÿ‡ฏ ๐Ÿ‡ง๐Ÿ‡ผ ๐Ÿ‡ง๐Ÿ‡ซ ๐Ÿ‡จ๐Ÿ‡ป ๐Ÿ‡จ๐Ÿ‡ซ ๐Ÿ‡น๐Ÿ‡ฉ ๐Ÿ‡ฐ๐Ÿ‡ฒ ๐Ÿ‡จ๐Ÿ‡ฎ ๐Ÿ‡จ๐Ÿ‡ฉ ๐Ÿ‡ฉ๐Ÿ‡ฏ ๐Ÿ‡ธ๐Ÿ‡ฟ ๐Ÿ‡ช๐Ÿ‡น ๐Ÿ‡ฌ๐Ÿ‡ฆ ๐Ÿ‡ฌ๐Ÿ‡ฒ ๐Ÿ‡ฌ๐Ÿ‡ญ ๐Ÿ‡ฌ๐Ÿ‡ณ ๐Ÿ‡ฌ๐Ÿ‡ผ ๐Ÿ‡ฐ๐Ÿ‡ช ๐Ÿ‡ฑ๐Ÿ‡ธ ๐Ÿ‡ฑ๐Ÿ‡ท ๐Ÿ‡ฒ๐Ÿ‡ฌ ๐Ÿ‡ฒ๐Ÿ‡ผ ๐Ÿ‡ฒ๐Ÿ‡ฑ ๐Ÿ‡ฒ๐Ÿ‡บ ๐Ÿ‡ฒ๐Ÿ‡ฟ ๐Ÿ‡ณ๐Ÿ‡ฆ ๐Ÿ‡ณ๐Ÿ‡ช ๐Ÿ‡ณ๐Ÿ‡ฌ ๐Ÿ‡จ๐Ÿ‡ฌ ๐Ÿ‡ท๐Ÿ‡ผ ๐Ÿ‡ธ๐Ÿ‡ณ ๐Ÿ‡ธ๐Ÿ‡ฑ ๐Ÿ‡ฟ๐Ÿ‡ฆ ๐Ÿ‡ธ๐Ÿ‡น ๐Ÿ‡น๐Ÿ‡ฟ ๐Ÿ‡น๐Ÿ‡ฌ ๐Ÿ‡บ๐Ÿ‡ฌ ๐Ÿ‡ฟ๐Ÿ‡ฒ
E ๐Ÿ‡ฆ๐Ÿ‡ฌ ๐Ÿ‡ฆ๐Ÿ‡ผ ๐Ÿ‡ง๐Ÿ‡ธ ๐Ÿ‡ง๐Ÿ‡ง ๐Ÿ‡ง๐Ÿ‡ฟ ๐Ÿ‡ป๐Ÿ‡ฌ ๐Ÿ‡จ๐Ÿ‡ผ ๐Ÿ‡ฉ๐Ÿ‡ฒ ๐Ÿ‡ฌ๐Ÿ‡ฉ ๐Ÿ‡ฌ๐Ÿ‡พ ๐Ÿ‡ญ๐Ÿ‡น ๐Ÿ‡ฏ๐Ÿ‡ฒ ๐Ÿ‡ฒ๐Ÿ‡ธ NE ๐Ÿ‡ฐ๐Ÿ‡ณ ๐Ÿ‡ฑ๐Ÿ‡จ ๐Ÿ‡ป๐Ÿ‡จ ๐Ÿ‡น๐Ÿ‡น
IL ๐Ÿ‡ฎ๐Ÿ‡ฑ
JO ๐Ÿ‡ฏ๐Ÿ‡ด
KR ๐Ÿ‡ฐ๐Ÿ‡ท
MA ๐Ÿ‡ฒ๐Ÿ‡ฆ
OM ๐Ÿ‡ด๐Ÿ‡ฒ
P ๐Ÿ‡จ๐Ÿ‡ท ๐Ÿ‡ฉ๐Ÿ‡ด ๐Ÿ‡ธ๐Ÿ‡ป ๐Ÿ‡ฌ๐Ÿ‡น ๐Ÿ‡ญ๐Ÿ‡ณ ๐Ÿ‡ณ๐Ÿ‡ฎ
PA ๐Ÿ‡ต๐Ÿ‡ฆ
PE ๐Ÿ‡ต๐Ÿ‡ช
S ๐Ÿ‡จ๐Ÿ‡ฆ ๐Ÿ‡ฒ๐Ÿ‡ฝ
SG ๐Ÿ‡ธ๐Ÿ‡ฌ
Column 2 Rate of Duty33ยข/kg + 25%
Quota QuantityN/A
Additional DutiesN/A

Overview

This HTS subcategory encompasses medium density fiberboard (MDF) that is between 5 mm and 9 mm in thickness. Crucially, these boards are characterized by having been tongued, grooved, or rabbetted continuously along any of their edges. Furthermore, their design and construction must specifically indicate dedication for use in the construction of walls, ceilings, or other architectural components of buildings. This means the edge profiling is not merely decorative but functional for interlocking or joining pieces in building applications.

The distinction from its sibling category, 4411.13.30.00 "Other," lies in the specific edge treatment and intended end-use. While the sibling category would cover MDF of the same thickness but without the continuous tongued, grooved, or rabbetted edges, or if these edge features are not designed for building applications, this subcategory precisely captures those boards specifically engineered for integrated installation within building structures. The continuous profiling is key to distinguishing these specialized building panels.

As this classification represents a leaf node within the HTS, there are no further subcategories. Classification at this level is definitive based on the material (MDF), thickness range (exceeding 5 mm but not exceeding 9 mm), the presence of continuous tongued, grooved, or rabbetted edges, and its designated application in building construction. Examples would include tongue-and-groove MDF panels for interior wall cladding or ceiling tiles designed for a suspended grid system where the edges interlock.

Stay Updated

Join our newsletter to get all updates of the harmonized Tariff Schedule.